Amersham Hot Start Mix Ready-To-Go, 0.2ml tube, 96 reactions-CYTIVA 28900653

Cytiva

MPN:
28900653
Sales Unit:
EACH
Amersham Hot Start Mix Ready-To-Go
$349.23
Order & Product Policies Learn more about Shipping and Returns
Recombinant hot start activator protein sequesters primers prior to PCR, effectively reducing nonspecific priming and primerdimer formation. Avoids the risk of contamination from a mammalian source associated with hot start antibodies. Quick hot start activation preserves sample integrity by avoiding extensive precycling heat treatment. Streamlines the workflow and yields more reproducible results. Longterm ambienttemperature stable: no freezer space required; less energy consumption for shipping and storage Validated for realtime PCR. Hot Start Mix RTG is a premixed, predispensed, ambient temperature stable formulation that can effectively reduce nonspecific priming and primerdimer formation during PCR. The system is based on a novel hot start method that uses a hot start activator protein to sequester primers prior to PCR, thereby making them unavailable for nonspecific priming during the reaction preparation. This method requires only a quick 2 min initial PCR activation step. In contrast, other commercially available hot start PCR kits that are based on chemical inactivation require prolonged incubation at high temperatures, which may damage the DNA template by heatinduced depurination. The net result from using Hot Start Mix RTG is a more robust and reliable amplification of the target amplicons with increased yield when compared with conventional hot start master mix products. Furthermore, the mix does not contain Taq antibody and this eliminates the risk of mammaliansource contamination. The advantages of the Raedy-To-Go (RTG) format over other hot start mixes include increased reproducibility, longterm storage at room temperature, and a more convenient reaction setup. You can expect consistent and reliable PCR results with Hot Start Mix RTG because we have minimized pipetting steps and reduced the potential for errors and contamination. The only additional reagents required are water, primers, and template DNA. Additional MgCl2 can be easily added, allowing users to customize this reagent to their specific needs. The beads are provided predispensed into either NA.2ml or NA.5ml PCR tubes that are compatible with most thermal cyclers. The NA.2 ml tubes come assembled in a 96well (8 × 12) plate format that allows individual strips of eight tubes to be easily removed. This flexibility allows use of the entire 96well plate, strips of eight, or individual NA.2 ml tubes. This Raedy-To-Go format provides reproducible and reliable performance for demanding PCR applications in which high specificity and high sensitivity are essential to success.